Question
What Error codes and how to check when using Smar Construction Edge2?
Answer
As of October 2024: This table list is compatible with software versions up to version 5
It is scheduled to be updated sequentially with software updates.
Error Code | Error | Troubleshooting steps・Items to confirm |
90304001 | An error occurred in SMART CONSTRUCTION Edge. Shutdown the unit and turn it back on. If this error occurs repeatedly, note the error code and contact us. |
Please contact support with the time of occurrence (UTC) and error code. |
90400001 | Fail to generate point cloud. | Please contact support with the time of occurrence and error code. Please provide flight data and PPKlog. Daily precautions Immediately after battery replacement, a flight interval of several minutes (3 minutes or more) is required. Periodic Inspection Please free up at least 50 GB of storage space. Please make sure FW is up-to-date Multiple flights Please check if each flight can be handled individually. |
93204002 | The temperature of SMART CONSTRUCTION Edge is outside the allowable range. Shutdown SMART CONSTRUCTION Edge for safety. |
Place the Edgebox2 in a cool place to lower the temperature and then turn the power on again. When the unit is hot, make sure the cooling fan on the Edgebox2 unit is turning. If the cooling fan does not turn, please get in touch with support. |
93301001 | An error occurred in SMART CONSTRUCTION Edge. Shutdown the unit and turn it back on. If this error occurs repeatedly, note the error code and contact us. |
Tablet and Edge2 need to be restarted and reconnected Please contact support with the time of occurrence, error code and period of use |
90200000 | none | Tends to occur when reading flight data It affects the flight immediately after battery replacement. (After battery replacement, it is necessary to wait for at least 3 minutes.) Setup as a fixed station There may be an error in the imported CSV. The format needs to be reviewed. Other Flight data may be incomplete. Re-flight should be considered and an analysis request should be made. (Please share the name and specifications of the SD card you are using.) Please contact support with the time of occurrence and error code. Translated with www.DeepL.com/Translator (free version) |
A0200000 | An error occurred in SMART CONSTRUCTION Edge. Shutdown the unit and turn it back on. If this error occurs repeatedly, note the error code and contact us. |
Please contact support with the time of occurrence (UTC) and error code. |
A0201003 | An error occurred in SMART CONSTRUCTION Edge. Shutdown the unit and turn it back on. If this error occurs repeatedly, note the error code and contact us. |
Please reconfirm the CSV format |
A0202001 | Could not delete. Please check the job/event list and the send list to see if any processes are running, and perform the following checks before deleting again If there is a process in progress, cancel it. If the result of the process is displayed, clear the list. |
Waiting is required until processing is complete. |
A0203001 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0203002 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0204001 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0204002 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0204003 | Failed to import data. Delete unnecessary data from SMART CONSTRUCTION Edge. |
Unnecessary data inside the Edge2 unit needs to be deleted. (sufficient free storage is required). |
A0204004 | Fail to export data. There is not enough free space in the USB memory. |
Unnecessary data inside the Edge2 unit needs to be deleted. (sufficient free storage is required). |
A0204005 | Cannot delete because it is linked or under processing. Please retry after the process. |
You need to wait until the processing is completed, including the reserved portion. |
A0205001 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0205002 | none | Please wait until the point cloud processing is finished. If you are not processing a point cloud, please reboot the device. (Because the process of deleting failed data is started at the time of startup.) |
A0205004 | Failed to import data. Delete unnecessary data from SMART CONSTRUCTION Edge. |
Unnecessary data inside the Edge2 unit needs to be deleted. (sufficient free storage is required). |
A0206001 | Removed flight data required for point cloud generation. Please retry from the beginning. |
Please reprocess the flight data after importing it. |
A0206002 | Fail to generate point cloud. No corresponding PPK log for flight data. |
Please PPK logs should be checked to see if they have been obtained for more than the flight time. If there is a problem with the PPK log, please re-flight. |
A0206003 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0206004 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0206006 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0206007 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0206008 | Cannot delete because it is linked or under processing. Please retry after the process. |
Waiting is required until processing is complete. |
A0206009 | Wait for it to complete, or select and remove the point cloud data being exported and export it again. | Waiting is required until processing is complete. |
A020600B | Fail to generate point cloud. No corresponding PPK log for flight data. |
PPK logs and flight data should be checked If there is a problem with the data, please re-flight. If data is OK, please provide PPK logs and flight data to support |
A020600C | Fail to export data. There is not enough free space in the USB memory. |
USB flash drive storage must be sufficient Delete unnecessary data on the USB |
A020C000 | none | Unnecessary data inside the Edge2 unit needs to be deleted. (sufficient free storage is required). |
A020C006 | Fail to export data. Make sure that the USB flash drive is inserted into SMART CONSTRUCTION Edge. |
Reinsert the USB memory stick or try another USB memory stick |
A0300001 | Cannot connect to network RTK service. Check if Internet communication is stable. |
You may not be able to use (receive) the Ntrip service. Please change to another Ntrip service to see if you can receive the data. |
A0300002 | Authentication failed. | Network RKT service is unavailable. First time: Need to check for ID and PASS input errors During use: Checking for service suspension and duplicate IDs is required |
A0300003 | I can't communicate with external radio. Check the radio settings and retry. |
External radio connection needs to be confirmed |
A0300004 | GNSS Positioning failed. | The Edge2 device is not able to provide GNSS positioning. GNSS reception environment and reception conditions need to be checked. |
A0300005 | Fail to save PPK log. Delete unnecessary data from SMART CONSTRUCTION Edge. |
Unnecessary data inside the Edge2 unit needs to be deleted. (sufficient free storage is required). |
A0300006 | Fail to save PPK log. | Please contact support with the time of occurrence (UTC) and error code. |
A0303002 | Distribution has been suspended due to a network error Please make sure that you have a stable Internet connection. |
Network connection confirmation is required |
A0400002 | Fail to transform coordinate system. | Please check if the EPSG codes match |
A0400003 | Fail to load the flight data. | Please check if your drone is compatible with Edge2 |
A0500001 | Fail to PPK process. | Please try to re-flight If re-flight does not improve, please provide PPK logs and flight data to support |
A0701002 | Fail to generate point cloud. | Please try to re-flight If re-flight does not improve, please provide PPK logs and flight data to support |
A0701003 | Fail to generate point cloud. | When processing multiple flight data in one batch, You need to make sure that they are the same image size. |
A0701006 | Fail to generate point cloud. | There may be insufficient memory. It is necessary to take action such as freeing up storage on the Edge2 device. Checkpoints If the camera angle in drone was accidentally changed Please try to re-fly the drone. |
A070100A | Fail to generate point cloud. | Please check if each flight data is successfully processed by itself Possible insufficient wrap of flight data Pre-flight check Check for drone airframe and camera malfunctions and remove lens caps prior to flight If re-flight does not improve the problem, please provide PPK log and flight data to support |
A070100F | Fail to generate point cloud. | The number of photos in the flight data needs to be checked. Please contact support with the time of occurrence and error code. |
A0701010 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702001 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702002 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702003 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702004 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702005 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A0702006 | Fail to generate point cloud. | Please contact support with the time of occurrence (UTC) and error code. |
A6A01001 | Internet communication is not available. If you are using Ethernet, make sure that the cable is connected properly. If you are using LTE, make sure that the settings are correct. |
Please check your LTE or wired LAN connection Please open a browser on your tablet and check if search is available. |
A6A01002 | An error occurred on the destination server. Note the error code and contact to us. |
You may not be able to log in to the application as an authentication error. Check if you are already logged in. Check if you are using the app in a location with poor internet connection. |
A6A01003 | Authentication failed. | Checkpoint Users must confirm that they are a user who has purchased the Smar Construction Dashboard. You must confirm that you are the user who purchased the Smar Construction Dashboard. Please try the below. Sign out and sign in from the app of Edge2. |
B020C003 | none | USGive each folder on the USB memory stick a unique name for each project, and be careful not to duplicate names. |
Comments