Issue
Error code 0xA0500001: PPK processing does not start.
Answer/Cause
0xA0500001 indicates PPK failure or PPK does not fix.
Explanation / How to deal
1. Check if the mask angle in the setting is set to 10 degrees.
2. The order of PPK logging may be incorrect.
Start logging ⇒ Turn on the drone power ⇒ Fly ⇒ Turn off the drone power ⇒ Logging end
Re-flight with the order above in mind.
3.If there is a discrepancy between the EDGE2 installation position and the actual logging position, the above error will occur and PPK processing will not be possible. Please make sure that the actual installation point and height are correct.
*If EDGE2 is installed at an arbitrary point and the tripod has been removed, it will be necessary to measure the VRS again and add a new point.